Resmed Astral 150 Portable Ventilator
ResMed Astral 150 ventilator offers excellence in invasive and non-invasive ventilation without compromise. From initial setup to everyday use, Astral offers greater freedom, confident care, and designed efficiency to enrich life for you and your patients. Astral’s discreet and lightweight design coupled with 24-hour run time (with a combination of internal and external batteries) provides greater freedom and makes patient transfers easier. It delivers excellence in leak and valve ventilation for invasive and non-invasive applications as well as providing a full suite of therapy modes to suit adult and paediatric applications. With easy setup, simple servicing, and an intuitive interface, Astral is designed to make ventilation support straightforward and efficient
Resmed Astral 150 Ventilator Highlights
Personalized for patient comfort
With nine different therapy modes, including the newly added iVAPS, Astral offers the ultimate in personalized comfort. With offerings of the single leak, single valve, and double limb circuits, you can cater to a wide range of patient types – from adults to pediatric patients weighing as little as 5kgs. For patients requiring oxygen therapy, Astral accommodates flow rates of 30 L/min, with integrated FiO2 monitoring in Astral 150 for fine-tuning oxygen therapy
Designed with efficiency in mind
Astral’s award-winning design, easy setup, and simple servicing make ventilation support straightforward and efficient.
Quick and easy setup: Astral’s intuitive navigation and menus streamline staff training and enable the consistent and accurate patient setup. And with QuickConnect’”, you can easily incorporate two pressure lines into one.
Multiple programs for therapy flexibility: Using up to four pre-settable programs, patients with treatment requirements that change under particular conditions (e.g. day/night or with/without humidification) can be transitioned easily from one therapy program to another without ventilation interruption.
Simple maintenance options: Pneumatic block replacement is only required every 35,000 hours and can be quickly and seamlessly replaced during an in-field service or at the service center, reducing downtime for the device and improving cost efficiencies.
Technical Specifications
Model | Astral 150 |
---|---|
Indications for use | Life support for patients over 5 kg* |
Circuit | |
Single circuit with leak | ✓ |
Single circuit with valve | ✓ |
Double circuit | ✓ |
Therapy | |
Valve circuit therapy: CPAP, ACV, PACV, P-SIMV, V-SIMV, PS | ✓ |
Leak circuit therapy: CPAP, ST, PAC, iVAPS* | ✓ |
Manual breath | ✓ |
Sigh breath (recruitment) | ✓ |
Apnoea ventilation | Volume and pressure |
Preset programs | 4 |
Pressure Range and Settings | |
Delivered pressure (cm H2O) | 2–50 (leak circuit)
0–50 (valve circuit) |
Delivered tidal volume (mL) | Adult: 100–2500 mL
Paediatric: 50–300 mL |
Respiratory rate | Adult: Off, 2–50 bpm
Paediatric: Off, 5–80 bpm |
Data | |
SpO2 monitoring | Optional |
FiO2 monitoring | ✓ |
On screen | 30 days of summary data
Real-time pressure and flow (25 Hz) |
ResScan (via download) | 365 days of summary data
7 days of detailed data |
Alarms – a wide range of settable alarms are available including FiO2 and SpO2 when connected. | |
Dimensions | |
Weight | 3.2 kg |
Dimensions (L x W x H) | 285 mm x 215 mm x 93 mm |
Sound power level | 43 ± 3 dBA** |
Sound pressure level | 35 ± 3 dBA** |
Reviews